| HIGH VOLTAGE ANODE
Instruction For Discharging HV Anode
Attach a 2 foot wire to screwdriver as shown in Screwdriver
Setup picture below. Attach wire to the ground strap that is
around outside of picture tube.
Slide Screwdriver under suction cup of the anode lead as shown in
Discharge Demo picture. This should cause an arch that can be
heard. Hold screwdriver in this position for 30 seconds. Lift a
section of the anode cup and push the terminal over to release
anode cup from picture tube. On RCA sets push a screwdriver
under cup as you are holding one side of cup up and using
screwdriver push the terminal over to release it from tube.
Pictures of these cups are shown to give a better view of what
it looks like under the suction cup. Do not touch any metal part
of this suction cup while releasing cup. There will be some
slight amount of charge still on the anode.




TVModule.com/Barrett Enterprize are in no way responsible for
injury or damage resulting from these instruction, if any. These
instruction are for your benefit only. |